New 2010 ASHRAE Ventilation Standard Passed

New 2010 ASHRAE Ventilation Standard Passed | Facility Executive - Creating Intelligent Buildings


http://facilityexecutive.com/2010/06/new-2010-ashrae-ventilation-standard-passed/
New requirements regarding natural ventilation, exhaust systems, and the IAQ Procedure are included in the newly published 2010 version of Standard 62.1.

New 2010 ASHRAE Ventilation Standard Passed

Facebooktwittergoogle_plusredditpinterestlinkedintumblrmail

New 2010 ASHRAE Ventilation Standard Passed

New requirements regarding natural ventilation, exhaust systems, and the IAQ Procedure are included in the newly published 2010 version of Standard 62.1. ANSI/ASHRAE Standard 62.1-2010, Ventilation for Acceptable Indoor Air Quality, sets minimum ventilation rates and other requirements for commercial and institutional buildings.

“Since first being published in 1973, the standard has provided the basis for ventilation system design throughout the industry,” Roger Hedrick, committee chair, said. “The 2010 standard furthers ASHRAE’s work in ensuring acceptable indoor air quality, while also heeding the need for energy efficiency as we strive to find ways to help designers tailor ventilation system designs to each particular application.”

Among the changes to the 2010 standard are modifications to the Natural Ventilation Rate Procedure, which now requires most buildings designed to meet the natural ventilation requirements also include a mechanical ventilation system designed to meet the Ventilation Rate or IAQ procedures. The mechanical system is to be used when windows are closed due to extreme outdoor temperatures, noise, and security concerns.

“Most buildings using natural ventilation in the United States are high-rise residential buildings that often have no form of outdoor air intake other than operable windows,” Hedrick said. “This results in buildings with inadequate ventilation, because occupants often leave the windows closed in order to run the air conditioning, keep out noise, etc. The committee felt it needed to strengthen the existing prescriptive requirements to ensure adequate ventilation and their corresponding IAQ benefits are available to occupants.”

Another change relocates requirements related to exhaust systems to a new section, clarifying that exhaust requirements apply to all buildings regardless of the procedure used to determine outdoor air intake flow rates.

The IAQ procedure, which allows for the calculation of the amount of outdoor air necessary to maintain the levels of indoor air contaminants below recommended levels, has been made more robust by increasing requirements for using the “similar building” design approach and clarifying other requirements.

“The standard now contains, in informative Appendix B, a table of volatile organic compounds that designers might want to consider as possible contaminants of concern,” Hedrick said. “To encourage designers to consider ‘additivity’ when applying the IAQ Procedure, some guidance from the American Conference of Governmental Industrial Hygienists has been included.”

The cost of Standard 62.1-2010, Ventilation for Acceptable Indoor Air Quality, is $69 ($59 ASHRAE members). To order, visit the ASHRAE Bookstore.

You Might Like:

  • Building Envelope: Energy Use And IAQBuilding envelope improvements often rank at or near the top of the facility team’s to-do list, since they generally provide an attractive return on investment.
  • ASHRAE Funds Thermal Comfort Database ProjectCreation of a database to help better understand human thermal comfort in residential and commercial buildings is being funded through an ASHRAE grant program.
  • TruBTU® by Cambridge EngineeringTruBTU is an app that helps determine the best and most efficient means for heating and ventilating a space.
  • Wind-Driven Rain Louver From GreenheckThe new Model EVH-901 dual module louver provides for high volume intake and exhaust ventilation and protects against water penetration even under the most severe wind-driven rain conditions.

1 COMMENT

  1. Great Blog of ASHRAE ventilation.
    Good atmosphere makes good results. Air circulation plays an important role in keeping the atmosphere clean and safe.

Comments are closed.