Danfoss Offers VLT Preferred Harmonic Drives Panel

These harmonic drives offer a solution for optimized harmonic performance and increases flexibility by reducing harmonics at a wide range.

Harmonic Drives
Danfoss’ VLT® Preferred Harmonic Drives (PHD) offer optimum harmonic mitigation and input power factor performance. Their ability to accomplish this at full load and substantially reduced loading from both utility line or standby/backup generator power makes them an ideal solution for HVAC fans and pumps.

The key to the design of this low harmonic drive solution is a specialized input power section that has the unique capability of adapting to load changes. Traditionally, low harmonic drives need to run at or above 80% load power to provide any reasonable level of reduction in Total Harmonic Distortion or THiD.  But in many instances, the drive running an HVAC fan or pump will be called on to run at reduced speed. While reducing the speed provides tremendous energy savings, it is still important to keep harmonic distortion under control. The adaptive feature embedded in the VLT PHD panel keeps THiD levels below 5% even when the input power load is reduced to 60% of the drive rated capacity.

The VLT PHD is also generator friendly. Historically a generator would have to be oversized to handle the high harmonic current draw at heavy load. While a low harmonic packaged drive solves this problem, it often creates another problem—leading power factor at lightly loaded conditions. This leading power factor condition (also known as capacitive current) is typical of many other low harmonic drive designs and may cause problems when running at light load, since most power generators do not operate well with leading power factor and may fault or go unstable with as little as 20% leading current.

The PHD solution provides two important added benefits that help reduce leading power factor. First, the adaptive input power circuit allows for a much lower level of capacitance at the line input. This in turn results in very low leading power factor over all load conditions. Second, the PHD drive panel has a built-in cut-out circuit interlocked with the drive control board to disconnect filtering capacitors and virtually eliminate leading power factor at very light and no loads operating conditions.

By providing harmonic compliance at the input terminals of the drive, this solution also does a better job of helping customers meet the requirements of IEEE-519, the governing document that sets the standard for allowable harmonic distortion limits.

Click here for more products in HVAC.

FacilityBlog, Featured Products & Services, Indoor Air Quality (IAQ), New Product Flash, Product News, Products & Services, Property Services

Danfoss, generator, harmonic distortion limits, harmonic drive solution, harmonic drives, HVAC, HVAC fans, IEEE-519, PHD drive panel, PHD solution, power factor condition, THiD, Total Harmonic Distortion, VLT PHD, VLT® Preferred Harmonic Drives (PHD)

Sponsored Content
Featured Video

Webinars, Podcasts & Videos

crime scene

Listen Now: What To Do When Your Facility Becomes A Crime Scene

A business continuity analyst discusses steps FM teams need to consider after a crime has been committed in their buildings.

Facilities Teams, ARC Facilities Webinar

Did You Miss Our “Solving The Hidden Assets Challenge” Webinar?

Hidden assets can be a challenge for facilities teams. View this free video webinar on demand and learn how your team can retain knowledge and streamline operations.

Job Order Contracting: Accelerating the Projects that Matter

This proven single-solicitation process accelerates project delivery while satisfying local bidding requirements. Learn all about Gordian’s JOC solutions .

Receive the latest articles in your inbox

Share to...